hw/block/nvme: support namespace detach
Given that now we have nvme-subsys device supported, we can manage
namespace allocated, but not attached: detached. This patch introduced
a parameter for nvme-ns device named 'detached'. This parameter
indicates whether the given namespace device is detached from
a entire NVMe subsystem('subsys' given case, shared namespace) or a
controller('bus' given case, private namespace).
- Allocated namespace
1) Shared ns in the subsystem 'subsys0':
-device nvme-ns,id=ns1,drive=blknvme0,nsid=1,subsys=subsys0,detached=true
2) Private ns for the controller 'nvme0' of the subsystem 'subsys0':
-device nvme-subsys,id=subsys0
-device nvme,serial=foo,id=nvme0,subsys=subsys0
-device nvme-ns,id=ns1,drive=blknvme0,nsid=1,bus=nvme0,detached=true
3) (Invalid case) Controller 'nvme0' has no subsystem to manage ns:
-device nvme,serial=foo,id=nvme0
-device nvme-ns,id=ns1,drive=blknvme0,nsid=1,bus=nvme0,detached=true
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
-rw-r--r-- | hw/block/nvme-ns.c | 1 | ||||
-rw-r--r-- | hw/block/nvme-ns.h | 1 | ||||
-rw-r--r-- | hw/block/nvme-subsys.h | 1 | ||||
-rw-r--r-- | hw/block/nvme.c | 41 | ||||
-rw-r--r-- | hw/block/nvme.h | 22 |
5 files changed, 64 insertions, 2 deletions
diff --git a/hw/block/nvme-ns.c b/hw/block/nvme-ns.c index 0e87600204..eda6a0c003 100644 --- a/hw/block/nvme-ns.c +++ b/hw/block/nvme-ns.c @@ -399,6 +399,7 @@ static Property nvme_ns_props[] = { DEFINE_BLOCK_PROPERTIES(NvmeNamespace, blkconf), DEFINE_PROP_LINK("subsys", NvmeNamespace, subsys, TYPE_NVME_SUBSYS, NvmeSubsystem *), + DEFINE_PROP_BOOL("detached", NvmeNamespace, params.detached, false), DEFINE_PROP_UINT32("nsid", NvmeNamespace, params.nsid, 0), DEFINE_PROP_UUID("uuid", NvmeNamespace, params.uuid), DEFINE_PROP_UINT16("mssrl", NvmeNamespace, params.mssrl, 128), diff --git a/hw/block/nvme-ns.h b/hw/block/nvme-ns.h index 7af6884862..b0c00e115d 100644 --- a/hw/block/nvme-ns.h +++ b/hw/block/nvme-ns.h @@ -26,6 +26,7 @@ typedef struct NvmeZone { } NvmeZone; typedef struct NvmeNamespaceParams { + bool detached; uint32_t nsid; QemuUUID uuid; diff --git a/hw/block/nvme-subsys.h b/hw/block/nvme-subsys.h index 7a54a85120..507efcd23f 100644 --- a/hw/block/nvme-subsys.h +++ b/hw/block/nvme-subsys.h @@ -23,6 +23,7 @@ typedef struct NvmeSubsystem { uint8_t subnqn[256]; NvmeCtrl *ctrls[NVME_SUBSYS_MAX_CTRLS]; + /* Allocated namespaces for this subsystem */ NvmeNamespace *namespaces[NVME_SUBSYS_MAX_NAMESPACES]; struct { diff --git a/hw/block/nvme.c b/hw/block/nvme.c index bfab80c457..1790a66cb8 100644 --- a/hw/block/nvme.c +++ b/hw/block/nvme.c @@ -27,7 +27,7 @@ * subsys=<subsys_id> * -device nvme-ns,drive=<drive_id>,bus=<bus_name>,nsid=<nsid>,\ * zoned=<true|false[optional]>, \ - * subsys=<subsys_id> + * subsys=<subsys_id>,detached=<true|false[optional]> * * Note cmb_size_mb denotes size of CMB in MB. CMB is assumed to be at * offset 0 in BAR2 and supports only WDS, RDS and SQS for now. By default, the @@ -91,6 +91,13 @@ * subsystem. Otherwise, `bus` must be given to attach this namespace to a * specific controller as a non-shared namespace. * + * - `detached` + * This parameter is only valid together with the `subsys` parameter. If left + * at the default value (`false/off`), the namespace will be attached to all + * controllers in the NVMe subsystem at boot-up. If set to `true/on`, the + * namespace will be be available in the subsystem not not attached to any + * controllers. + * * Setting `zoned` to true selects Zoned Command Set at the namespace. * In this case, the following namespace properties are available to configure * zoned operation: @@ -4655,6 +4662,20 @@ static void nvme_init_state(NvmeCtrl *n) n->aer_reqs = g_new0(NvmeRequest *, n->params.aerl + 1); } +static int nvme_attach_namespace(NvmeCtrl *n, NvmeNamespace *ns, Error **errp) +{ + if (nvme_ns_is_attached(n, ns)) { + error_setg(errp, + "namespace %d is already attached to controller %d", + nvme_nsid(ns), n->cntlid); + return -1; + } + + nvme_ns_attach(n, ns); + + return 0; +} + int nvme_register_namespace(NvmeCtrl *n, NvmeNamespace *ns, Error **errp) { uint32_t nsid = nvme_nsid(ns); @@ -4686,7 +4707,23 @@ int nvme_register_namespace(NvmeCtrl *n, NvmeNamespace *ns, Error **errp) trace_pci_nvme_register_namespace(nsid); - n->namespaces[nsid - 1] = ns; + /* + * If subsys is not given, namespae is always attached to the controller + * because there's no subsystem to manage namespace allocation. + */ + if (!n->subsys) { + if (ns->params.detached) { + error_setg(errp, + "detached needs nvme-subsys specified nvme or nvme-ns"); + return -1; + } + + return nvme_attach_namespace(n, ns, errp); + } else { + if (!ns->params.detached) { + return nvme_attach_namespace(n, ns, errp); + } + } n->dmrsl = MIN_NON_ZERO(n->dmrsl, BDRV_REQUEST_MAX_BYTES / nvme_l2b(ns, 1)); diff --git a/hw/block/nvme.h b/hw/block/nvme.h index 96afefa8c9..cd8d406344 100644 --- a/hw/block/nvme.h +++ b/hw/block/nvme.h @@ -189,6 +189,10 @@ typedef struct NvmeCtrl { NvmeSubsystem *subsys; NvmeNamespace namespace; + /* + * Attached namespaces to this controller. If subsys is not given, all + * namespaces in this list will always be attached. + */ NvmeNamespace *namespaces[NVME_MAX_NAMESPACES]; NvmeSQueue **sq; NvmeCQueue **cq; @@ -207,6 +211,24 @@ static inline NvmeNamespace *nvme_ns(NvmeCtrl *n, uint32_t nsid) return n->namespaces[nsid - 1]; } +static inline bool nvme_ns_is_attached(NvmeCtrl *n, NvmeNamespace *ns) +{ + int nsid; + + for (nsid = 1; nsid <= n->num_namespaces; nsid++) { + if (nvme_ns(n, nsid) == ns) { + return true; + } + } + + return false; +} + +static inline void nvme_ns_attach(NvmeCtrl *n, NvmeNamespace *ns) +{ + n->namespaces[nvme_nsid(ns) - 1] = ns; +} + static inline NvmeCQueue *nvme_cq(NvmeRequest *req) { NvmeSQueue *sq = req->sq; |