authorKlaus Jensen2021-03-23 12:43:24 +0100
committerKlaus Jensen2021-04-07 10:48:31 +0200
commite5489356349a400774c1bda60dbf78cff211e009 (patch)
tree1c9fbda2a27f0aa4f7d04d615724392152c1cd76 /hw/block/trace-events
parenthw/block/nvme: update dmsrl limit on namespace detachment (diff)
downloadqemu-e5489356349a400774c1bda60dbf78cff211e009.tar.gz
qemu-e5489356349a400774c1bda60dbf78cff211e009.tar.xz
qemu-e5489356349a400774c1bda60dbf78cff211e009.zip
hw/block/nvme: fix handling of private namespaces
Prior to this patch, if a private nvme-ns device (that is, a namespace that is not linked to a subsystem) is wired up to an nvme-subsys linked nvme controller device, the device fails to verify that the namespace id is unique within the subsystem. NVM Express v1.4b, Section 6.1.6 ("NSID and Namespace Usage") states that because the device supports Namespace Management, "NSIDs *shall* be unique within the NVM subsystem". Additionally, prior to this patch, private namespaces are not known to the subsystem and the namespace is considered exclusive to the controller with which it is initially wired up to. However, this is not the definition of a private namespace; per Section 1.6.33 ("private namespace"), a private namespace is just a namespace that does not support multipath I/O or namespace sharing, which means "that it is only able to be attached to one controller at a time". Fix this by always allocating namespaces in the subsystem (if one is linked to the controller), regardless of the shared/private status of the namespace. Whether or not the namespace is shareable is controlled by a new `shared` nvme-ns parameter. Finally, this fix allows the nvme-ns `subsys` parameter to be removed, since the `shared` parameter now serves the purpose of attaching the namespace to all controllers in the subsystem upon device realization. It is invalid to have an nvme-ns namespace device with a linked subsystem without the parent nvme controller device also being linked to one and since the nvme-ns devices will unconditionally be "attached" (in QEMU terms that is) to an nvme controller device through an NvmeBus, the nvme-ns namespace device can always get a reference to the subsystem of the controller it is explicitly (using 'bus=' parameter) or implicitly attaching to. Fixes: e570768566b3 ("hw/block/nvme: support for shared namespace in subsystem") Cc: Minwoo Im <minwoo.im.dev@gmail.com> Signed-off-by: Klaus Jensen <k.jensen@samsung.com> Reviewed-by: Gollu Appalanaidu <anaidu.gollu@samsung.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Diffstat (limited to 'hw/block/trace-events')
-rw-r--r--hw/block/trace-events1
1 files changed, 0 insertions, 1 deletions
diff --git a/hw/block/trace-events b/hw/block/trace-events
index 22da06986d..fa12e3a67a 100644
--- a/hw/block/trace-events
+++ b/hw/block/trace-events
@@ -51,7 +51,6 @@ hd_geometry_guess(void *blk, uint32_t cyls, uint32_t heads, uint32_t secs, int t
# nvme.c
# nvme traces for successful events
-pci_nvme_register_namespace(uint32_t nsid) "nsid %"PRIu32""
pci_nvme_irq_msix(uint32_t vector) "raising MSI-X IRQ vector %u"
pci_nvme_irq_pin(void) "pulsing IRQ pin"