summaryrefslogtreecommitdiffstats
path: root/hw
diff options
context:
space:
mode:
authorMinwoo Im2021-01-24 03:54:50 +0100
committerKlaus Jensen2021-03-09 11:00:57 +0100
commite570768566b36f0a0471f65a40b47a6471ef0e24 (patch)
tree6298ce6c7c9ecfefb1cbbe026a250c37b1164dda /hw
parenthw/block/nvme: add NMIC enum value for Identify Namespace (diff)
downloadqemu-e570768566b36f0a0471f65a40b47a6471ef0e24.tar.gz
qemu-e570768566b36f0a0471f65a40b47a6471ef0e24.tar.xz
qemu-e570768566b36f0a0471f65a40b47a6471ef0e24.zip
hw/block/nvme: support for shared namespace in subsystem
nvme-ns device is registered to a nvme controller device during the initialization in nvme_register_namespace() in case that 'bus' property is given which means it's mapped to a single controller. This patch introduced a new property 'subsys' just like the controller device instance did to map a namespace to a NVMe subsystem. If 'subsys' property is given to the nvme-ns device, it will belong to the specified subsystem and will be attached to all controllers in that subsystem by enabling shared namespace capability in NMIC(Namespace Multi-path I/O and Namespace Capabilities) in Identify Namespace. Usage: -device nvme-subsys,id=subsys0 -device nvme,serial=foo,id=nvme0,subsys=subsys0 -device nvme,serial=bar,id=nvme1,subsys=subsys0 -device nvme,serial=baz,id=nvme2,subsys=subsys0 -device nvme-ns,id=ns1,drive=<drv>,nsid=1,subsys=subsys0 # Shared -device nvme-ns,id=ns2,drive=<drv>,nsid=2,bus=nvme2 # Non-shared In the above example, 'ns1' will be shared to 'nvme0' and 'nvme1' in the same subsystem. On the other hand, 'ns2' will be attached to the 'nvme2' only as a private namespace in that subsystem. All the namespace with 'subsys' parameter will attach all controllers in the subsystem to the namespace by default. Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com> Tested-by: Klaus Jensen <k.jensen@samsung.com> Reviewed-by: Klaus Jensen <k.jensen@samsung.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Diffstat (limited to 'hw')
-rw-r--r--hw/block/nvme-ns.c17
-rw-r--r--hw/block/nvme-ns.h7
-rw-r--r--hw/block/nvme-subsys.c25
-rw-r--r--hw/block/nvme-subsys.h3
-rw-r--r--hw/block/nvme.c10
5 files changed, 58 insertions, 4 deletions
diff --git a/hw/block/nvme-ns.c b/hw/block/nvme-ns.c
index 93ac6e107a..64b6a491ad 100644
--- a/hw/block/nvme-ns.c
+++ b/hw/block/nvme-ns.c
@@ -63,6 +63,10 @@ static int nvme_ns_init(NvmeNamespace *ns, Error **errp)
id_ns->npda = id_ns->npdg = npdg - 1;
+ if (nvme_ns_shared(ns)) {
+ id_ns->nmic |= NVME_NMIC_NS_SHARED;
+ }
+
return 0;
}
@@ -363,14 +367,21 @@ static void nvme_ns_realize(DeviceState *dev, Error **errp)
return;
}
- if (nvme_register_namespace(n, ns, errp)) {
- return;
+ if (ns->subsys) {
+ if (nvme_subsys_register_ns(ns, errp)) {
+ return;
+ }
+ } else {
+ if (nvme_register_namespace(n, ns, errp)) {
+ return;
+ }
}
-
}
static Property nvme_ns_props[] = {
DEFINE_BLOCK_PROPERTIES(NvmeNamespace, blkconf),
+ DEFINE_PROP_LINK("subsys", NvmeNamespace, subsys, TYPE_NVME_SUBSYS,
+ NvmeSubsystem *),
DEFINE_PROP_UINT32("nsid", NvmeNamespace, params.nsid, 0),
DEFINE_PROP_UUID("uuid", NvmeNamespace, params.uuid),
DEFINE_PROP_BOOL("zoned", NvmeNamespace, params.zoned, false),
diff --git a/hw/block/nvme-ns.h b/hw/block/nvme-ns.h
index 293ac990e3..929e788619 100644
--- a/hw/block/nvme-ns.h
+++ b/hw/block/nvme-ns.h
@@ -47,6 +47,8 @@ typedef struct NvmeNamespace {
const uint32_t *iocs;
uint8_t csi;
+ NvmeSubsystem *subsys;
+
NvmeIdNsZoned *id_ns_zoned;
NvmeZone *zone_array;
QTAILQ_HEAD(, NvmeZone) exp_open_zones;
@@ -77,6 +79,11 @@ static inline uint32_t nvme_nsid(NvmeNamespace *ns)
return -1;
}
+static inline bool nvme_ns_shared(NvmeNamespace *ns)
+{
+ return !!ns->subsys;
+}
+
static inline NvmeLBAF *nvme_ns_lbaf(NvmeNamespace *ns)
{
NvmeIdNs *id_ns = &ns->id_ns;
diff --git a/hw/block/nvme-subsys.c b/hw/block/nvme-subsys.c
index 283a97b79d..af4804a819 100644
--- a/hw/block/nvme-subsys.c
+++ b/hw/block/nvme-subsys.c
@@ -43,6 +43,31 @@ int nvme_subsys_register_ctrl(NvmeCtrl *n, Error **errp)
return cntlid;
}
+int nvme_subsys_register_ns(NvmeNamespace *ns, Error **errp)
+{
+ NvmeSubsystem *subsys = ns->subsys;
+ NvmeCtrl *n;
+ int i;
+
+ if (subsys->namespaces[nvme_nsid(ns)]) {
+ error_setg(errp, "namespace %d already registerd to subsy %s",
+ nvme_nsid(ns), subsys->parent_obj.id);
+ return -1;
+ }
+
+ subsys->namespaces[nvme_nsid(ns)] = ns;
+
+ for (i = 0; i < ARRAY_SIZE(subsys->ctrls); i++) {
+ n = subsys->ctrls[i];
+
+ if (n && nvme_register_namespace(n, ns, errp)) {
+ return -1;
+ }
+ }
+
+ return 0;
+}
+
static void nvme_subsys_setup(NvmeSubsystem *subsys)
{
const char *nqn = subsys->params.nqn ?
diff --git a/hw/block/nvme-subsys.h b/hw/block/nvme-subsys.h
index 55411eccfb..7a54a85120 100644
--- a/hw/block/nvme-subsys.h
+++ b/hw/block/nvme-subsys.h
@@ -14,6 +14,7 @@
OBJECT_CHECK(NvmeSubsystem, (obj), TYPE_NVME_SUBSYS)
#define NVME_SUBSYS_MAX_CTRLS 32
+#define NVME_SUBSYS_MAX_NAMESPACES 32
typedef struct NvmeCtrl NvmeCtrl;
typedef struct NvmeNamespace NvmeNamespace;
@@ -22,6 +23,7 @@ typedef struct NvmeSubsystem {
uint8_t subnqn[256];
NvmeCtrl *ctrls[NVME_SUBSYS_MAX_CTRLS];
+ NvmeNamespace *namespaces[NVME_SUBSYS_MAX_NAMESPACES];
struct {
char *nqn;
@@ -29,5 +31,6 @@ typedef struct NvmeSubsystem {
} NvmeSubsystem;
int nvme_subsys_register_ctrl(NvmeCtrl *n, Error **errp);
+int nvme_subsys_register_ns(NvmeNamespace *ns, Error **errp);
#endif /* NVME_SUBSYS_H */
diff --git a/hw/block/nvme.c b/hw/block/nvme.c
index 5a63c356ba..5e0819fd9e 100644
--- a/hw/block/nvme.c
+++ b/hw/block/nvme.c
@@ -26,7 +26,8 @@
* mdts=<N[optional]>,zoned.append_size_limit=<N[optional]>, \
* subsys=<subsys_id>
* -device nvme-ns,drive=<drive_id>,bus=<bus_name>,nsid=<nsid>,\
- * zoned=<true|false[optional]>
+ * zoned=<true|false[optional]>, \
+ * subsys=<subsys_id>
*
* Note cmb_size_mb denotes size of CMB in MB. CMB is assumed to be at
* offset 0 in BAR2 and supports only WDS, RDS and SQS for now. By default, the
@@ -79,6 +80,13 @@
* data size being in effect. By setting this property to 0, users can make
* ZASL to be equal to MDTS. This property only affects zoned namespaces.
*
+ * nvme namespace device parameters
+ * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+ * - `subsys`
+ * If given, the namespace will be attached to all controllers in the
+ * subsystem. Otherwise, `bus` must be given to attach this namespace to a
+ * specific controller as a non-shared namespace.
+ *
* Setting `zoned` to true selects Zoned Command Set at the namespace.
* In this case, the following namespace properties are available to configure
* zoned operation: