summaryrefslogtreecommitdiffstats
path: root/drivers/gpu/drm/i915/intel_pm.c
diff options
context:
space:
mode:
authorVille Syrjälä2014-06-27 18:49:57 +0200
committerDaniel Vetter2014-08-08 17:43:56 +0200
commit3dd7b97458e8aa2d8985b46622d226fa635071e7 (patch)
treeefa9cc74dc12fbd04aeafa498f9f9d3ecf9a4b3b /drivers/gpu/drm/i915/intel_pm.c
parentdrm/i915: Add cherryview_update_wm() (diff)
downloadkernel-qcow2-linux-3dd7b97458e8aa2d8985b46622d226fa635071e7.tar.gz
kernel-qcow2-linux-3dd7b97458e8aa2d8985b46622d226fa635071e7.tar.xz
kernel-qcow2-linux-3dd7b97458e8aa2d8985b46622d226fa635071e7.zip
drm/i915: Hack to tie both common lanes together on chv
It looks like frobbing the cmnreset line on pne PHY disturbs the other PHY on chv. The result is a black screen. On HDMI it's just a flash of black, but DP usually falls over and can't get back up. As a workaround set up the power domains so that both common lane wells power up and down together. I also tried leaving the cmnreset deasserted even the if the power well goes down but that didn't seem acceptable to the PHY. Reviewed-by: Rafael Barbalho <rafael.barbalho@intel.com> Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Diffstat (limited to 'drivers/gpu/drm/i915/intel_pm.c')
-rw-r--r--drivers/gpu/drm/i915/intel_pm.c14
1 files changed, 12 insertions, 2 deletions
diff --git a/drivers/gpu/drm/i915/intel_pm.c b/drivers/gpu/drm/i915/intel_pm.c
index da43e30ad60b..aaae22815965 100644
--- a/drivers/gpu/drm/i915/intel_pm.c
+++ b/drivers/gpu/drm/i915/intel_pm.c
@@ -6877,13 +6877,23 @@ static struct i915_power_well chv_power_wells[] = {
#endif
{
.name = "dpio-common-bc",
- .domains = CHV_DPIO_CMN_BC_POWER_DOMAINS,
+ /*
+ * XXX: cmnreset for one PHY seems to disturb the other.
+ * As a workaround keep both powered on at the same
+ * time for now.
+ */
+ .domains = CHV_DPIO_CMN_BC_POWER_DOMAINS | CHV_DPIO_CMN_D_POWER_DOMAINS,
.data = PUNIT_POWER_WELL_DPIO_CMN_BC,
.ops = &chv_dpio_cmn_power_well_ops,
},
{
.name = "dpio-common-d",
- .domains = CHV_DPIO_CMN_D_POWER_DOMAINS,
+ /*
+ * XXX: cmnreset for one PHY seems to disturb the other.
+ * As a workaround keep both powered on at the same
+ * time for now.
+ */
+ .domains = CHV_DPIO_CMN_BC_POWER_DOMAINS | CHV_DPIO_CMN_D_POWER_DOMAINS,
.data = PUNIT_POWER_WELL_DPIO_CMN_D,
.ops = &chv_dpio_cmn_power_well_ops,
},