summaryrefslogtreecommitdiffstats
path: root/drivers/scsi
diff options
context:
space:
mode:
authorSreekanth Reddy2013-02-01 17:19:30 +0100
committerJames Bottomley2013-02-24 09:48:15 +0100
commit7887ea7f942770c2146dbcdfa2a85aa8de93df31 (patch)
treeac74a72d1daf5a64dea0340331780cef0af1f898 /drivers/scsi
parent[SCSI] ipr: Fix oops while resetting an ipr adapter (diff)
downloadkernel-qcow2-linux-7887ea7f942770c2146dbcdfa2a85aa8de93df31.tar.gz
kernel-qcow2-linux-7887ea7f942770c2146dbcdfa2a85aa8de93df31.tar.xz
kernel-qcow2-linux-7887ea7f942770c2146dbcdfa2a85aa8de93df31.zip
[SCSI] mpt2sas: Add support for OEM specific controller
Defined SSDID & HW vendor brand strings. Added entries for SSDID within the function that prints the brand string. Signed-off-by: Sreekanth Reddy <Sreekanth.Reddy@lsi.com> Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Diffstat (limited to 'drivers/scsi')
-rw-r--r--drivers/scsi/mpt2sas/mpt2sas_base.c8
-rw-r--r--drivers/scsi/mpt2sas/mpt2sas_base.h6
2 files changed, 14 insertions, 0 deletions
diff --git a/drivers/scsi/mpt2sas/mpt2sas_base.c b/drivers/scsi/mpt2sas/mpt2sas_base.c
index 5e24e7e73714..bcb23d28b3e8 100644
--- a/drivers/scsi/mpt2sas/mpt2sas_base.c
+++ b/drivers/scsi/mpt2sas/mpt2sas_base.c
@@ -2023,6 +2023,14 @@ _base_display_intel_branding(struct MPT2SAS_ADAPTER *ioc)
printk(MPT2SAS_INFO_FMT "%s\n", ioc->name,
MPT2SAS_INTEL_RMS25KB040_BRANDING);
break;
+ case MPT2SAS_INTEL_RMS25LB040_SSDID:
+ printk(MPT2SAS_INFO_FMT "%s\n", ioc->name,
+ MPT2SAS_INTEL_RMS25LB040_BRANDING);
+ break;
+ case MPT2SAS_INTEL_RMS25LB080_SSDID:
+ printk(MPT2SAS_INFO_FMT "%s\n", ioc->name,
+ MPT2SAS_INTEL_RMS25LB080_BRANDING);
+ break;
default:
break;
}
diff --git a/drivers/scsi/mpt2sas/mpt2sas_base.h b/drivers/scsi/mpt2sas/mpt2sas_base.h
index c6ee7aad7501..4caaac13682f 100644
--- a/drivers/scsi/mpt2sas/mpt2sas_base.h
+++ b/drivers/scsi/mpt2sas/mpt2sas_base.h
@@ -165,6 +165,10 @@
"Intel(R) Integrated RAID Module RMS25KB080"
#define MPT2SAS_INTEL_RMS25KB040_BRANDING \
"Intel(R) Integrated RAID Module RMS25KB040"
+#define MPT2SAS_INTEL_RMS25LB040_BRANDING \
+ "Intel(R) Integrated RAID Module RMS25LB040"
+#define MPT2SAS_INTEL_RMS25LB080_BRANDING \
+ "Intel(R) Integrated RAID Module RMS25LB080"
#define MPT2SAS_INTEL_RMS2LL080_BRANDING \
"Intel Integrated RAID Module RMS2LL080"
#define MPT2SAS_INTEL_RMS2LL040_BRANDING \
@@ -180,6 +184,8 @@
#define MPT2SAS_INTEL_RMS25JB040_SSDID 0x3517
#define MPT2SAS_INTEL_RMS25KB080_SSDID 0x3518
#define MPT2SAS_INTEL_RMS25KB040_SSDID 0x3519
+#define MPT2SAS_INTEL_RMS25LB040_SSDID 0x351A
+#define MPT2SAS_INTEL_RMS25LB080_SSDID 0x351B
#define MPT2SAS_INTEL_RMS2LL080_SSDID 0x350E
#define MPT2SAS_INTEL_RMS2LL040_SSDID 0x350F
#define MPT2SAS_INTEL_RS25GB008_SSDID 0x3000