summaryrefslogtreecommitdiffstats
path: root/drivers/staging/comedi
diff options
context:
space:
mode:
authorIan Abbott2009-04-14 17:06:27 +0200
committerGreg Kroah-Hartman2009-06-19 20:00:30 +0200
commit0d6e5dad12c5a2860e3d13b4d7a4702f90386003 (patch)
tree7fff86afbd007f504b68e12ed1a6f384c5bdc95a /drivers/staging/comedi
parentStaging: comedi: Undo stupid commit made 3 months ago (diff)
downloadkernel-qcow2-linux-0d6e5dad12c5a2860e3d13b4d7a4702f90386003.tar.gz
kernel-qcow2-linux-0d6e5dad12c5a2860e3d13b4d7a4702f90386003.tar.xz
kernel-qcow2-linux-0d6e5dad12c5a2860e3d13b4d7a4702f90386003.zip
Staging: comedi: amplc_pc236: Corrected documentation.
Interrupt is triggered by rising edge on port C bit 3 (not bit 7). From: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Frank Mori Hess <fmhess@users.sourceforge.net> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to 'drivers/staging/comedi')
-rw-r--r--drivers/staging/comedi/drivers/amplc_pc236.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/staging/comedi/drivers/amplc_pc236.c b/drivers/staging/comedi/drivers/amplc_pc236.c
index 294500361b0c..fc1a8f1b611a 100644
--- a/drivers/staging/comedi/drivers/amplc_pc236.c
+++ b/drivers/staging/comedi/drivers/amplc_pc236.c
@@ -27,7 +27,7 @@ Driver: amplc_pc236
Description: Amplicon PC36AT, PCI236
Author: Ian Abbott <abbotti@mev.co.uk>
Devices: [Amplicon] PC36AT (pc36at), PCI236 (pci236 or amplc_pc236)
-Updated: Wed, 22 Oct 2008 13:40:03 +0100
+Updated: Wed, 01 Apr 2009 15:41:25 +0100
Status: works
Configuration options - PC36AT:
@@ -45,7 +45,7 @@ as subdevice 0.
Subdevice 1 pretends to be a digital input device, but it always returns
0 when read. However, if you run a command with scan_begin_src=TRIG_EXT,
-a rising edge on port C bit 7 acts as an external trigger, which can be
+a rising edge on port C bit 3 acts as an external trigger, which can be
used to wake up tasks. This is like the comedi_parport device, but the
only way to physically disable the interrupt on the PC36AT is to remove
the IRQ jumper. If no interrupt is connected, then subdevice 1 is