summaryrefslogtreecommitdiffstats
path: root/drivers/net/pcnet32.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/pcnet32.c')
-rw-r--r--drivers/net/pcnet32.c23
1 files changed, 16 insertions, 7 deletions
diff --git a/drivers/net/pcnet32.c b/drivers/net/pcnet32.c
index 31e6dd049859..549a07385884 100644
--- a/drivers/net/pcnet32.c
+++ b/drivers/net/pcnet32.c
@@ -22,8 +22,8 @@
*************************************************************************/
#define DRV_NAME "pcnet32"
-#define DRV_VERSION "1.31b"
-#define DRV_RELDATE "06.Oct.2005"
+#define DRV_VERSION "1.31c"
+#define DRV_RELDATE "01.Nov.2005"
#define PFX DRV_NAME ": "
static const char *version =
@@ -262,6 +262,9 @@ static int homepna[MAX_UNITS];
* to allow loopback test to work unchanged.
* v1.31b 06 Oct 2005 Don Fry changed alloc_ring to show name of device
* if allocation fails
+ * v1.31c 01 Nov 2005 Don Fry Allied Telesyn 2700/2701 FX are 100Mbit only.
+ * Force 100Mbit FD if Auto (ASEL) is selected.
+ * See Bugzilla 2669 and 4551.
*/
@@ -1612,12 +1615,18 @@ pcnet32_open(struct net_device *dev)
val |= 0x10;
lp->a.write_csr (ioaddr, 124, val);
- /* Allied Telesyn AT 2700/2701 FX looses the link, so skip that */
+ /* Allied Telesyn AT 2700/2701 FX are 100Mbit only and do not negotiate */
if (lp->pci_dev->subsystem_vendor == PCI_VENDOR_ID_AT &&
- (lp->pci_dev->subsystem_device == PCI_SUBDEVICE_ID_AT_2700FX ||
- lp->pci_dev->subsystem_device == PCI_SUBDEVICE_ID_AT_2701FX)) {
- printk(KERN_DEBUG "%s: Skipping PHY selection.\n", dev->name);
- } else {
+ (lp->pci_dev->subsystem_device == PCI_SUBDEVICE_ID_AT_2700FX ||
+ lp->pci_dev->subsystem_device == PCI_SUBDEVICE_ID_AT_2701FX)) {
+ if (lp->options & PCNET32_PORT_ASEL) {
+ lp->options = PCNET32_PORT_FD | PCNET32_PORT_100;
+ if (netif_msg_link(lp))
+ printk(KERN_DEBUG "%s: Setting 100Mb-Full Duplex.\n",
+ dev->name);
+ }
+ }
+ {
/*
* 24 Jun 2004 according AMD, in order to change the PHY,
* DANAS (or DISPM for 79C976) must be set; then select the speed,