1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
|
.\" Copyright (c) 1983, 1990, 1993
.\" The Regents of the University of California. All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\" 3. All advertising materials mentioning features or use of this software
.\" must display the following acknowledgement:
.\" This product includes software developed by the University of
.\" California, Berkeley and its contributors.
.\" 4. Neither the name of the University nor the names of its contributors
.\" may be used to endorse or promote products derived from this software
.\" without specific prior written permission.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" @(#)logger.1 8.1 (Berkeley) 6/6/93
.\"
.TH LOGGER "1" "November 2015" "util-linux" "User Commands"
.SH NAME
logger \- enter messages into the system log
.SH SYNOPSIS
.B logger
[options]
.RI [ message ]
.SH DESCRIPTION
.B logger
makes entries in the system log.
.sp
When the optional \fImessage\fR argument is present, it is written
to the log. If it is not present, and the \fB\-f\fR option is not
given either, then standard input is logged.
.SH OPTIONS
.TP
.BR \-d , " \-\-udp"
Use datagrams (UDP) only. By default the connection is tried to the
syslog port defined in /etc/services, which is often 514 .
.sp
See also \fB\-\-server\fR and \fB\-\-socket\fR to specify where to connect.
.TP
.BR \-e , " \-\-skip-empty"
Ignore empty lines when processing files. An empty line
is defined to be a line without any characters. Thus a line consisting
only of whitespace is NOT considered empty.
Note that when the \fB\-\-prio\-prefix\fR option is specified, the priority
is not part of the line. Thus an empty line in this mode is a line that does
not have any characters after the priority prefix (e.g. \fB<13>\fR).
.TP
.BR \-f , " \-\-file " \fIfile
Log the contents of the specified \fIfile\fR.
This option cannot be combined with a command-line message.
.TP
.B \-i
Log the PID of the logger process with each line.
.TP
.BR "\-\-id" [ =\fIid ]
Log the PID of the logger process with each line. When the optional
argument \fIid\fR is specified, then it is used instead of the logger
command's PID. The use of \fB\-\-id=$$\fR
(PPID) is recommended in scripts that send several messages.
Note that the system logging infrastructure (for example \fBsystemd\fR when
listening on /dev/log) may follow local socket credentials to overwrite the
PID specified in the message.
.BR logger (1)
is able to set those socket credentials to the given \fIid\fR, but only if you
have root permissions and a process with the specified PID exists, otherwise
the socket credentials are not modified and the problem is silently ignored.
.TP
.BR \-\-journald [ =\fIfile ]
Write a systemd journal entry. The entry is read from the given \fIfile\fR,
when specified, otherwise from standard input.
Each line must begin with a field that is accepted by journald; see
.BR systemd.journal-fields (7)
for details. The use of a MESSAGE_ID field is generally a good idea, as it
makes finding entries easy. Examples:
.IP
.nf
\fB logger \-\-journald <<end
\fB MESSAGE_ID=67feb6ffbaf24c5cbec13c008dd72309
\fB MESSAGE=The dogs bark, but the caravan goes on.
\fB DOGS=bark
\fB CARAVAN=goes on
\fB end
.IP
\fB logger \-\-journald=entry.txt
.fi
.IP
Notice that
.B \-\-journald
will ignore values of other options, such as priority. If priority is
needed it must be within input, and use PRIORITY field. The simple
execution of
.B journalctl
will display MESSAGE field. Use
.B journalctl \-\-output json-pretty
to see rest of the fields.
.sp
To include newlines in MESSAGE, specify MESSAGE several times. This is
handled as a special case, other fields will be stored as an array in
the journal if they appear multiple times.
.TP
.BR \-\-msgid " \fImsgid
Sets the RFC5424 MSGID field. Note that the space character is not permitted
inside of \fImsgid\fR. This option is only used if \fB\-\-rfc5424\fR is
specified as well; otherwise, it is silently ignored.
.TP
.BR \-n , " \-\-server " \fIserver
Write to the specified remote syslog \fIserver\fR
instead of to the system log socket. Unless
\fB\-\-udp\fR or \fB\-\-tcp\fR
is specified, \fBlogger\fR will first try to use UDP,
but if this fails a TCP connection is attempted.
.TP
.B \-\-no\-act
Causes everything to be done except for writing the log message to the system
log, and removing the connection or the journal. This option can be used
together with \fB\-\-stderr\fR for testing purposes.
.TP
.B \-\-octet\-count
Use the RFC 6587 octet counting framing method for sending messages.
When this option is not used, the default is no framing on UDP, and
RFC6587 non-transparent framing (also known as octet stuffing) on TCP.
.TP
.BR \-P , " \-\-port " \fIport
Use the specified \fIport\fR. When this option is not specified, the
port defaults to syslog for udp and to syslog-conn for tcp connections.
.TP
.BR \-p , " \-\-priority " \fIpriority
Enter the message into the log with the specified \fIpriority\fR.
The priority may be specified numerically or as a
.IR facility . level
pair.
For example, \fB\-p local3.info\fR
logs the message as informational in the local3 facility.
The default is \fBuser.notice\fR.
.TP
.B \-\-prio\-prefix
Look for a syslog prefix on every line read from standard input.
This prefix is a decimal number within angle brackets that encodes both
the facility and the level. The number is constructed by multiplying the
facility by 8 and then adding the level. For example, \fBlocal0.info\fR,
meaning facility=16 and level=6, becomes \fB<134>\fR.
.sp
If the prefix contains no facility, the facility defaults to what is
specified by the \fB\-p\fR option. Similarly, if no prefix is provided,
the line is logged using the \fIpriority\fR given with \fB\-p\fR.
.sp
This option doesn't affect a command-line message.
.TP
.B \-\-rfc3164
Use the RFC 3164 BSD syslog protocol to submit messages to a remote server.
.TP
.BR \-\-rfc5424 [ =\fIwithout ]
Use the RFC 5424 syslog protocol to submit messages to a remote server.
The optional \fIwithout\fR argument can be a comma-separated list of
the following values: \fBnotq\fR, \fBnotime\fR, \fBnohost\fR.
The \fBnotq\fR value suppresses the time-quality structured data
from the submitted message. The time-quality information shows whether
the local clock was synchronized plus the maximum number of microseconds
the timestamp might be off. The time quality is also automatically
suppressed when \fB\-\-sd\-id timeQuality\fR is specified.
The \fBnotime\fR value (which implies \fBnotq\fR)
suppresses the complete sender timestamp that is in
ISO-8601 format, including microseconds and timezone.
The \fBnohost\fR value suppresses
.BR gethostname (2)
information from the message header.
.IP
The RFC 5424 protocol has been the default for
.B logger
since version 2.26.
.TP
.BR \-s , " \-\-stderr"
Output the message to standard error as well as to the system log.
.TP
.BR "\-\-sd\-id \fIname" [ @\fIdigits ]
Specifies a structured data element ID for an RFC 5424 message header. The
option has to be used before \fB\-\-sd\-param\fR to introduce a new element.
The number of structured data elements is unlimited. The ID (\fIname\fR plus
possibly \fB@\fIdigits\fR) is case-sensitive and uniquely identifies the type
and purpose of the element. The same ID must not exist more than once in
a message. The \fB@\fIdigits\fR part is required for user-defined
non-standardized IDs.
\fBlogger\fR currently generates the \fBtimeQuality\fR standardized element
only. RFC 5424 also describes the elements \fBorigin\fR (with parameters
ip, enterpriseId, software and swVersion) and \fBmeta\fR (with parameters
sequenceId, sysUpTime and language).
These element IDs may be specified without the \fB@\fIdigits\fR suffix.
.TP
.BR "\-\-sd\-param " \fIname ="\fIvalue\fB"
Specifies a structured data element parameter, a name and value pair.
The option has to be used after \fB\-\-sd\-id\fR and may be specified more
than once for the same element. Note that the quotation marks around
\fIvalue\fR are required and must be escaped on the command line.
.IP
.nf
\fB logger \-\-rfc5424 \-\-sd-id zoo@123 \\
\fB \-\-sd-param tiger=\\"hungry\\" \\
\fB \-\-sd-param zebra=\\"running\\" \\
\fB \-\-sd-id manager@123 \\
\fB \-\-sd-param onMeeting=\\"yes\\" \\
\fB "this is message"
.fi
.IP
produces:
.IP
.nf
\fB <13>1 2015-10-01T14:07:59.168662+02:00 ws kzak - - [timeQuality tzKnown="1" isSynced="1" syncAccuracy="218616"][zoo@123 tiger="hungry" zebra="running"][manager@123 onMeeting="yes"] this is message
.fi
.IP
.TP
.BR \-S , " -\-size " \fIsize
Sets the maximum permitted message size to \fIsize\fR. The default
is 1KiB characters, which is the limit traditionally used and specified
in RFC 3164. With RFC 5424, this limit has become flexible. A good assumption
is that RFC 5424 receivers can at least process 4KiB messages.
Most receivers accept messages larger than 1KiB over any type of syslog
protocol. As such, the \fB\-\-size\fR option affects logger in
all cases (not only when \fB\-\-rfc5424\fR was used).
Note: the message-size limit limits the overall message size, including
the syslog header. Header sizes vary depending on the selected options and
the hostname length. As a rule of thumb, headers are usually not longer than
50 to 80 characters. When selecting a maximum message size, it is important
to ensure that the receiver supports the max size as well, otherwise messages
may become truncated. Again, as a rule of thumb two to four KiB message size
should generally be OK, whereas anything larger should be verified to work.
.TP
.BR \-\-socket\-errors [ =\fImode ]
Print errors about Unix socket connections. The \fImode\fR can be a value of
\fBoff\fR, \fBon\fR, or \fBauto\fR. When the mode is auto logger will detect
if the init process is systemd, and if so assumption is made /dev/log can be
used early at boot. Other init systems lack of /dev/log will not cause errors
that is identical with messaging using
.BR openlog (3)
system call. The
.BR logger (1)
before version 2.26 used openlog, and hence was unable to detected loss of
messages sent to Unix sockets.
.IP
The default mode is \fBauto\fR. When errors are not enabled lost messages are
not communicated and will result to successful return value of
.BR logger (1)
invocation.
.TP
.BR \-T , " \-\-tcp"
Use stream (TCP) only. By default the connection is tried to the
.I syslog-conn
port defined in /etc/services, which is often
.IR 601 .
.sp
See also \fB\-\-server\fR and \fB\-\-socket\fR to specify where to connect.
.TP
.BR \-t , " \-\-tag " \fItag
Mark every line to be logged with the specified
.IR tag .
The default tag is the name of the user logged in on the terminal (or a user
name based on effective user ID).
.TP
.BR \-u , " \-\-socket " \fIsocket
Write to the specified
.I socket
instead of to the system log socket.
.TP
.B \-\-
End the argument list. This allows the \fImessage\fR
to start with a hyphen (\-).
.TP
.BR \-V , " \-\-version"
Display version information and exit.
.TP
.BR \-h , " \-\-help"
Display help text and exit.
.SH RETURN VALUE
The
.B logger
utility exits 0 on success, and >0 if an error occurs.
.SH FACILITIES AND LEVELS
Valid facility names are:
.IP
.nr WI \n(.lu-\n(.iu-\w'\fBauthpriv\fR'u-3n
.TS
tab(:);
l lw(\n(WIu).
\fBauth
\fBauthpriv\fR:for security information of a sensitive nature
\fBcron
\fBdaemon
\fBftp
\fBkern\fR:T{
cannot be generated from userspace process, automatically converted to \fBuser
T}
\fBlpr
\fBmail
\fBnews
\fBsyslog
\fBuser
\fBuucp
\fBlocal0
to:
\fBlocal7
\fBsecurity\fR:deprecated synonym for \fBauth
.TE
.PP
Valid level names are:
.IP
.TS
tab(:);
l l.
\fBemerg
\fBalert
\fBcrit
\fBerr
\fBwarning
\fBnotice
\fBinfo
\fBdebug
\fBpanic\fR:deprecated synonym for \fBemerg
\fBerror\fR:deprecated synonym for \fBerr
\fBwarn\fR:deprecated synonym for \fBwarning
.TE
.PP
For the priority order and intended purposes of these facilities and levels, see
.BR syslog (3).
.SH EXAMPLES
.B logger System rebooted
.br
.B logger \-p local0.notice \-t HOSTIDM \-f /dev/idmc
.br
.B logger \-n loghost.example.com System rebooted
.SH SEE ALSO
.BR journalctl (1),
.BR syslog (3),
.BR systemd.journal-fields (7)
.SH STANDARDS
The
.B logger
command is expected to be IEEE Std 1003.2 ("POSIX.2") compatible.
.SH AUTHORS
The
.B logger
command
was originally written by University of California in 1983-1993 and later
rewritten by
.MT kzak@redhat.com
Karel Zak
.ME ,
.MT rgerhards@adiscon.com
Rainer Gerhards
.ME
and
.MT kerolasa@iki.fi
Sami Kerola
.ME .
.SH AVAILABILITY
The logger command is part of the util-linux package and is available from
.UR https://\:www.kernel.org\:/pub\:/linux\:/utils\:/util-linux/
Linux Kernel Archive
.UE .
|